MANOMETERS
Vacuum gauge, vacuum gage signaled DM2005f, DV2005f, DA2005f
Description, specifications
Signaling device has 4 kind of performance in accordance with GOST 2405-68:
III performance - two normally closed contact;
IV performance two make contacts;
V performance - two blades: one break, the second closing;
VI design - two terminals: the first closing, the second break
Supply voltage up to 380 V AC and 220 V DC, operating current less than 0.5A for signaling device with sliding contacts max 1A signaling device with magnetic snap-action contacts
Breaking capacity of sliding contacts 20VA 10W DC and AC contacts with magnetic snap 50VA 30W DC and AC.
Standard design with magnetic snap-type approval certificate of measuring GSH.S.30.004.A № 21119
Compliance certificate ROSS RSH.ME65.V00917 TU 421200-114-0411113635-05 GOST 2405-88
GOST R 51522 (IEC 61326-1 -97)
Manometer designed for measurement of redundant and non-crystallizable vacuum pressure of liquids, gases and vapors, non corrosive to materials details exposed to media, including Oxygen, and the circuit or breaking the electrical circuits when the preset pressure limit
TECHNICAL SPECIFICATIONS MANOMETER
Measurement range in kgf/cm2
DM2005f from 0 to I; 1.6; 2,5; 4, 6, 10, 1b, 25, 40, 60;
100, 160, 250, 400, 600, 1000, 1600
DV2005f -1 to about
DA2005fot-1 to 0.6, 1.5, 3, 5, 9, 15, 24
Ambient temperature -50 to +60 ° C
Accuracy class - 1.5
Protection - 1R40
Diameter - 150mm
Average life - Yulet
Weight - not more than 0.9 kg
Material - Steel
Glass - organic
Fitting, Bourdon tube - brass, bronze
Tribko-sector mechanism - bronze, brass, stainless steel
Dial - aluminum alloy, painted white
Options: radial connector without flange, radial connection with back flange