Foil strain gauges
      At foil strain gauges a pickoff is executed from foil in thick 3..6 .
      Thickness of foil strain gauges less than wire and 30..50 mkm makes. Basic advantages of foil strain gauges it is been possibility of formation of tenzo grates of any form and effective taking of heat in the process of measuring, that allows to get a greater output signal at identical deformations. Foil strain gauges are not sensitive to transversal deformations and assume execution beginning from a 0,3 mm and higher. 
      Tenzo grates of domestic foil strain gauges, as a rule, make from constantan foil (-- 03 96-67). Electromechanics properties of foil within the limits of one party as compared to constantan differ in less constancy, and her heat treatment is less effective, therefore the working range of foil strain gauges does not exceed 3000..5000 mln^ -1, and temperature - 75..575 . Technology of making of foil tenzo grates is usually based on the use of actinic processes and in a most degree adjusted for a mass production. Foil strain gauges divide into next model modifications depending on the form of tenzo grates (fig. 1) : single-element rectangular for the linear measuring; two - or three element rectangular or rosette-like for measuring on areas with the flat tense state; special, used as tenzo transducers in membrane pickoffs; as chainlets of with a small base one - or two - element tenzo grates on general basis for measuring of deformations in the areas of concentration of tensions.
      Domestic industry mass-produces the foil strain gauges of next tipo sizes : single-element strain gauges of types of 2, 2, 1, -, - and - on pellicle basis with bases a 0,8..20 mm and by resistance 50.. ..400 Ohm; two - and three element strain gauges of types of 2 and on pellicle and paper basis with bases a from 5 to 15 mm and by resistance from 100 to 400 Ohm; rosette-like strain gauges of types of 2, 2, - and - on pellicle basis with bases a 0,8.. 10 mm and by resistance 50.. 140 Ohm; special for the membrane resilient elements of electromechanics transducers of types of 2 and 2 on pellicle basis by a diameter a 10..30 mm and by resistance 50..200 Ohm.

      The strain gauges of the transferred types are intended for measuring in the climatic range of temperatures (225..325 ), and also at enhanceable temperatures - (265..475 ). Recommended assembling glues: cyacrin for the strain gauges of 2, 2, -, -, -; glues of - 2 and - 9 for the strain gauges of 1 and 2; glue of - 4 for the strain gauges of -, -, -, - and -; varnish of - 931 for the strain gauges of 2, 2, 2, 2, 2 and 2.
      Maximum measureable deformation of 0,3%, creep at T= 295 To not over 0,5%.
/ english
Home  >>  Mechanical stress, strain >>  Foil strain gauges


Home

Temperature, thermoelectricity

Magnetic fields

Mechanical stress, strain

Force, pressure, displacement, flow

Humidity, gases

Photo effects, light

Ionizing radiation

Electricity, capacity, piezoelectricity

Physical properties of materials

Literature on transducers

News, exhibitions, conferences

About the project. Contacts






                                                                                                                                                              
  NEWS, ADVERTISING 
, ,
See also:
Temperature sensors, thermocouple             Sensors of mechanical stress
Force, pressure, flow                                    Phototransducers
Ionization transducers                                    Hall sensors
Contacts
Fig. 1. Forms of tenzo grates of foil strain gauges
and - single-element rectangular; - much element rectangular and rosette-like; in - membrane; a g is chainlets of small base grates
, . Sensors, transducers
Loading...
, , sensors, gauge